I Cannot add batch version.

aisoice

aisoice

Member
Dear All,

I have problem about PeopleSoft E1 8.10.
I can create new Batch, but I cannot add batch version (P98305).
How to solve this problem ??? Please help me.
Thanks

regards
willy
 
Hi Willy,

Please, provide us with more information.
Any error message and/or log entry?
What does it mean exactly "I can not add"?

Regards,

Zoltán
P.S.: Is your mouse and keyboard connected to the computer?
cool.gif
 
Hi Willy,

My first thought is that this been secured away from you.

Dave
 
Dear All,

I login to environment PY810.
I try to create Batch Application from OL (P98220) and success. But, when I try to Add Version from BV (P98305), the version there no.

But, if I login to environment PD810, I have no problem to create Batch Application and Add Version.

Please help me to solve the problem.

I am sorry, my english not good.


regards
willy
 
When I try to Add Version, I don't get error message.
But its version there no.

This is a jde.log :

548/3244 Tue Sep 09 09:22:16.234 jdb_ctl.c2803
Starting OneWorld

548/3244 Tue Sep 09 09:22:31.437 Env.cpp137
Solution Explorer Started


Note : The problem only in environment PY810.


thanks
willy
 
Hi Willy,

Are you sure, that the spec of the UBE exist on PY810 on the deployment server and on HTML Client? I suppose, you can check the first in F9861 table on 8.10 too as on XE.

Regards,

Zoltán
 
Hi Zoltan,

I running on Fat Client,
Platform : W2k server,
Tools Release : 8.93.
From BV (P98305) I try to Add Version, I don't get error message, but its version there no.

Can you help me to solve this problem?

Note : Report which I present previously is report from jde.log.


regards
willy
 
Hi Willy,

#1. Does the Add Batch Version form pops up and can you hit OK?
#2. Try to select "All Versions" from the Form menu on Batch Versions and find again. Do you see your version?
#3. Check F983051 table in UTB. Do you find an entry for your version?

Sign onto the problematical environmen on your fat client and compare the local spec of your UBE against PD810, PY810 and DV810 central objects with Visual ER Compare tool. What is your result?

Read you later & Regards,

Zoltán
 
Dear Zoltan,

#1. From P98305|W98305A, I click Add then appear Form W98305G, and I can hit OK.
After I input a Version and all field, I click OK, the screen should be go to form (W98305S), but actually after click OK, the screen will go back to (W98305A).

#2. I had tried All Version from Form, Display All Version, I can see All Version, but my version that I had created before Not on the list.

#3. I had check F983051 table in UTB and I can not find an entry for my version?


Do you have any suggest ?


Note : If I try in PD810, I have no problem for point 1, 2 and 3.


Thanks
Willy
 
Dear All,

Please help me to solve my problem.

I can create new Batch, but I cannot add batch version from BV (P98305).
How to solve this problem ???

1. From P98305|W98305A, I click Add then appear Form W98305G, and I can hit OK.
After I input a Version and all field, I click OK, the screen should be go to form (W98305S), but actually after click OK, the screen will go back to (W98305A).

2. I had tried All Version from Form, Display All Version, I can see All Version, but my version that I had created before Not on the list.

3. I had check F983051 table in UTB and I can not find an entry for my version?


Note :
We using PeopleSoft E1 8.10
Tools Release : 8.93.R1
Login from FAT CLIENT
If I try in PD810, I have no problem for point 1, 2 and 3.


Thanks
Willy
 
Willy,

I might be time to get a debug log to find out exactly what is happening.
 
Hi Willy,

[ QUOTE ]
If I try in PD810, I have no problem for point 1, 2 and 3.


[/ QUOTE ]

I suppose, your problem occurs on other Path Code, e.g. on DV810, PY810.

#1. Check, does the UBE spec exist on the affected Path Code.
- Check F9861 table
- try to Get or Check-Out the UBE

#2. Maybe OMW Activity Rules cause the problem. If you are experienced in them, check these too.

Regards,

Zoltán
 
Hai
We work in B7333. I think you had Created the UBE with out the Processing Option Template. If you Create a UBE (report) without Processing Option Template (DS) then you have to create the Version while using the Report Design Director.

If you has not created the UBE without PO Template, You Create a dummy PO Template and add the same to your Report.
Then you will be able to create the Version.

Regards
Parthiban M P
 
Dear All,

Thank you very much for your suggestion,
specially to Ken Wong, Zoltan, Parthiban, Peter and Dave.
My problem has been solved.
I check at P00948 (Work With Release/Data Source Map) Version List, E810.
In Version list there no "Version - PY810", possible someone there is delete.
So..., I try to add "Version - PY810", and I get error message "Duplicate...,bla...bla...bla...
I check in database F00948, Version - PY810 is there, but field "Release Number" is blank.
So..., I try to update "Release Number" from database F00948, after that I try to Add Version from P98305, and succeed.

Thank you very much.

Regards,
Willy
 
Back
Top