Error on WO Routing: Fetch from table F3112 failed

DSauve

DSauve

Legendary Poster
I've recently logged a call with JDE on this issue and thought I'd share the outcome. Our users were going into WO Routings (P3112) from either Enter/Change WO or Shop Floor Workbench. The processing options for both calling programs specified that version ZJDE0001 of P3112 be used. Whenever they made a change and clicked OK to exit out of the WO Routings program, a red error displayed on the status bar for less than a second, saying "Fetch from table F3112 failed", and in the jde.log file were four lines of error messages which basically complained about not being able to update the F4801Z1 table.

After testing, we found that the ZJDE0001 version of this program had become corrupted. I created a new version, and the program then worked fine. I pointed the calling programs to use the new version of P3112 and the problem is now gone. Somehow, the version specs were indicating that we wanted interoperability turned on, when in fact we don't use it at all.
 
Back