UBE’s from Scheduler stops working apparently with corrupted specs.

sv800

Active Member
UBE from Scheduler suddenly stops working apparently with corrupted specs.
UBE’s are ending without errors but are not picking any data.
Output: No data selected.

For example R42118 Release backorders didn’t pick any data (no data selected)
Then UBE submitted manually and print 3 pages.
Next run by scheduler it’s fine again.

Looks data selection (specs) is getting corrupted time by time.
The error is coming back days later.

This problem came with SP18.1, we did not have it with SP15.1

Suggestions?
 
Are you using the same versions for the scheduler as you are for manual submittion. Try creating a copy of you manual version witht he data selection set and secure the vrsion, chehk it in deploy etc. and set that version up in the scheduler and see what happens.

Here's what might be happening:-

If a user submits the version with his/her oun data selection that selection stays on the server until another user changes it an re-submits it. Since the scheduler is an automated process and is not smart enough to reset the version it simply uses the selection spece of the last submitted version. Therefore of you create a seperate scheduler version with security 2 then no user can change the selection so when the scheduler submits the version selection specs are always submitted.

Hope this helps some.
 